  1.        Document 2687
  2.  DOCN  M94A2687
  3.  TI    A fast, simple and visual HIV antibody test in Zambian sera/plasma.
  4.  DT    9412
  5.  AU    Musonda RM; Kaetano L; Chizu C; Mluanda F; Tropical Diseases Research
  6.        Centre, Ndola, Zambia.
  7.  SO    Int Conf AIDS. 1994 Aug 7-12;10(1):248 (abstract no. PB0421). Unique
  8.        Identifier : AIDSLINE ICA10/94369888
  9.  AB    OBJECTIVE: To evaluate the use of a simple/rapid test for detection of
  10.        antibodies against HIV-1/HIV-2 in patients sera and donors in Zambia.
  11.        METHODS: A total of 202 serum/plasma from successive, unselected
  12.        patients attending antenatal (ANC), gynaecology (gyea), medical,
  13.        sexually transmitted diseases (STD) clinic, medical check-up and blood
  14.        donors and 10 unknown sera from CDC were tested for antibodies against
  15.        HIV using the following HIV Test kits: (i) Capillus HIV-1/HIV-2 direct
  16.        latex agglutination (ii) Recombinant HIV-1/HIV-2 Rapid Test Device (RTD)
  17.        (iii) HIV-Spot HIV-1/HIV-2 (iv) Wellcozyme HIV Recombinant (ELISA)
  18.        VK56/57 (v) Wellcozyme HIV-1/HIV-2 ELISA VK54/55 and Western Blot as
  19.        final criteria for positivity and negativity. RESULTS: Of the 212
  20.        serum/plasma samples tested 63 sample were confirmed HIV antibody
  21.        positive. The sensitivity of the all five tests was 100% and 98% for
  22.        Wellcozyme VK56/57. However, only the Capillus and the RTD gave 100%
  23.        specificity and positive predictive value but the rest of the kits gave
  24.        specificity ranging from 98-86% and the Wellcozyme HIV-1/HIV-2 ELISA
  25.        gave the lowest positive predictive value. The Capillus was the
  26.        simplest, fastest test kit and no need for extra equipment, consumables,
  27.        power supply, or well trained manpower or technician. DISCUSSION AND
  28.        CONCLUSIONS: The Capilus latex agglutination test is suitable for both
  29.        small and large volume testing of blood samples/plasma/sera, for
  30.        emergency testing of blood donors, for sentinel surveillance or for
  31.        patients inclinical setting such as STD clinic where HIV testing and
  32.        counselling could be promptly implemented. Therefore, the Capillus test
  33.        kits is recommended for use in most countries in sub Saharan Africa
  34.        where the standard screening procedures are impractical or not available
  35.        or where the cost of buying an ELISA reader, a washer and equipment and
  36.        supplies of HIV testing can exceed the annual budget of the whole
  37.        hospital laboratory.
  38.  DE    AIDS Serodiagnosis/*METHODS  Blood Donors  Blotting, Western
  39.        Comparative Study  *Developing Countries  Enzyme-Linked Immunosorbent
  40.        Assay  Female  Human  HIV Antibodies/*BLOOD  HIV
  41.        Seropositivity/*DIAGNOSIS/IMMUNOLOGY  HIV-1/*IMMUNOLOGY
  42.        HIV-2/*IMMUNOLOGY  Male  Predictive Value of Tests  Pregnancy  Zambia
  43.        MEETING ABSTRACT
  44.  
  45.        SOURCE: National Library of Medicine.  NOTICE: This material may be